DC Fans Common Specifications
|
 |
| |
 |
 |
 |
|
 |
 |
| ■ Standard |
 |
|
| Vibration Test |
: |
Conforms to JIS C 60068-2-6 |
|
|
Amplitude: 1.5mm |
|
|
Frequency 10 to 55 Hz, 1 hour.
In each of the X, Y and Z directions. |
| Shock Test |
: |
Conforms to JIS C 60068-2-27 |
|
|
Acceleration 981 m/s2* |
|
|
Application time 6ms.
Once each in the X, Y and Z directions.* |
| *) |
1004KL, 1204KL, 1404KL,
1604KL, 1606KL, 1608KL, 2004KL, 2106KL, 2404KL,
2406GL, BM4515, BM5115, BM5125 and BM6015 Series The conditions of shock test on the listed models are as belows
Acceleration rate: 500 m/s2
Application time: 11ms
Once each in the X, Y and Z directions. |
|
|
|
|
Locked Rotor
Protection |
: |
The motor is protected from burnout in the locked rotor condition for 72
hours, at the rated voltage. |
| Polarity Protection |
: |
The fans are Reverse Polarity protected at the rated voltage. |
| Insulation Class |
: |
E class (UL: Class A) |
| Auto Restart |
: |
Most fan models provide current shut-down/auto restart function under locked
rotor conditions. |
|
|
 |
 |
 |
|
|
 |
| ■ Notes |
 |
|
Additional performance requirements may be determined between manufacturer
and customer, based on customer's request. |
Fans may be installed in a horizontal, vertical, or angled position. |
|
|