F225A Series
General Specifications
- Motor Protection
- :Locked rotor, Reverse polarity
- Insulation Resistance
- :10M Ohm min, measured with 500V DC between all leads shorted together and case
- Dielectric Withstand Voltage
- :AC500V 1minute
- Allowable Ambient Temperature Range
- :
-30 deg.C - +70 deg.C (Operating)
-40 deg.C - +80 deg.C (Storage)
non-condensing environment
Expected Life
40 deg.C 70,000hours (L10)Outline
Panel Out-cuts
Characteristic Curves
Material
- Impeller
- : Plastic
- Bearing
- : Ball Bearings
- Lead Wire
- : UL1015 AWG18
- +
- : Red
- −
- : Black
- Speed Control
- : Yellow
- Speed Signal
- : White
Specifications
Model | Nominal Voltage (V) |
Operating Voltage (V) |
Nominal Current (A)*1 |
Input Power (W)*1 |
Speed (rpm)*1 |
---|---|---|---|---|---|
F225A2-092-D0730 | 48 | 36 - 72 | 3.6 | 172.8 | 3600 |
F225A3-092-D0720 | 48 | 36 - 72 | 2.0 | 96.0 | 2900 |
F225A4-092-D0530 | 24 | 18 - 30 | 6.9 | 165.6 | 3600 |
F225A5-092-D0520 | 24 | 18 - 30 | 3.9 | 93.6 | 2900 |
Model | Max. Air Flow (CFM)*1 |
Max. Static Pressure (Pa)*1 |
Noise (dB)*1 |
Mass (g) |
---|---|---|---|---|
F225A2-092-D0730 | 756 | 904 | 79 | 2100 |
F225A3-092-D0720 | 600 | 582 | 74 | |
F225A4-092-D0530 | 756 | 904 | 79 | |
F225A5-092-D0520 | 600 | 582 | 74 |
*1 Average values in free air and rated voltage condition.